Tankless Water Heater Sizing: Flow Rate and Temperature Rise
A tankless water heater is sized by how much hot water it must deliver at once and how much it must heat the incoming water. Here is the method, step by step.
- Sizing metric: GPM at a specific temperature rise
- Temperature rise: Desired output temperature minus incoming water temperature
- Design condition: Coldest incoming water, usually winter
Get Your Water Heater Estimate in Charlotte, NC
Tell us what you need. An independent, licensed installer near you will follow up with next steps.
Tankless water heater sizing uses two numbers: peak simultaneous flow in gallons per minute (GPM) and temperature rise, the difference between incoming water temperature and the desired hot water temperature. Choose a unit whose rated GPM at that temperature rise meets or exceeds your peak flow, using winter incoming water temperatures.
- DOE suggested setting
- 120°F for most households
Tankless Water Heater Sizing: key facts
Key facts from this page, one line each.
- Tankless water heater
- is sized by peak simultaneous flow in GPM and temperature rise
- Temperature rise
- equals desired output temperature minus incoming water temperature
- US Department of Energy
- suggests 120°F as a setting for most households
- Tankless GPM rating
- decreases as temperature rise increases
- Gas tankless water heater
- needs a gas line sized for its maximum input and correct venting
- Incoming water temperature
- is lowest in winter
Why tankless water heater sizing differs from tank sizing
Tankless water heater sizing differs from tank sizing because a tankless unit stores no hot water. Instead of First Hour Rating, a tankless unit is rated by how many gallons per minute (GPM) it can heat at a given temperature rise. The unit must keep up with every hot water fixture running at the same moment.
A tank can cover a short burst of heavy demand from its stored supply. A tankless unit cannot; if demand exceeds its capacity, the water coming out is cooler. That makes the peak simultaneous demand the key number.
If you are still deciding on type, start with the tank vs tankless guide.
Fixture flow rates in GPM for tankless water heater sizing
Fixture flow rate is the number of gallons per minute a shower, faucet or appliance draws. Many fixtures list their maximum GPM on the fixture or packaging. Using your own fixtures' ratings gives a more accurate tankless water heater sizing estimate than generic figures copied from a chart.
Showerhead and faucet GPM ratings
Showerheads generally draw more GPM than bathroom faucets, and tubs fill at a high rate. Most hot water uses mix hot and cold, so the hot flow is lower than the fixture's full rating. Sizing on full fixture flow builds in a margin that many installers prefer.
Dishwashers and washing machines
Dishwashers and washing machines draw hot water intermittently rather than steadily. Check whether they typically run at the same time as showers in your home, because an overlapping laundry cycle on a busy morning adds to the peak GPM a tankless unit must meet.
Estimating peak simultaneous use for a tankless water heater
Peak simultaneous use is the set of hot water fixtures that realistically run at the same moment during your busiest time, such as two showers and a kitchen faucet on a weekday morning. Adding the flow rates of those fixtures gives the peak GPM a tankless water heater must deliver.
Be realistic rather than adding every fixture in the house. Few homes run every shower, tub and appliance at once. Overestimating leads to a larger, more expensive unit; underestimating leads to lukewarm showers.
- Identify the busiest moment of a typical day.
- List the hot water fixtures that run at that moment.
- Find each fixture's flow rate in GPM.
- Add them to get peak simultaneous flow.
The total from the last step is your peak simultaneous flow in GPM. Write it down, because the installer will match it against each model's flow-versus-rise chart.
Temperature rise and incoming water temperature in tankless sizing
Temperature rise is the number of degrees a tankless water heater must heat incoming water to reach the desired output temperature. Temperature rise equals the desired temperature minus the incoming water temperature. Incoming water is colder in winter, so tankless units should be sized for the coldest expected incoming water.
Manufacturers publish flow-versus-rise charts for each model, and the installer uses these to match the unit to your needs.
The 120°F output setting
The US Department of Energy suggests 120°F as a water heater setting for most households. Using that setting as the desired output temperature keeps the temperature rise calculation realistic and avoids sizing a tankless unit for hotter water than the household needs.
Winter incoming water temperature
Incoming water temperature drops in winter and varies with the water source and with pipes that run through unconditioned spaces. A well and a municipal supply can differ. A tankless unit's GPM rating falls as temperature rise increases, so size for the coldest expected incoming water.
Tankless water heater sizing worked example (hypothetical numbers)
A worked tankless sizing example shows the method using hypothetical numbers. Add the flow rates of fixtures used at once, calculate the temperature rise from assumed incoming and desired temperatures, then pick a model whose rated GPM at that rise meets the total. The figures below are an example only, not a recommendation.
Example only: assume a household where two showers and a kitchen faucet may run at the same time on a winter morning. The numbers below are illustrative; your fixtures and water temperatures will differ.
| Step | Example assumption | Example result |
|---|---|---|
| Shower 1 flow | Example: 2.0 GPM | 2.0 GPM |
| Shower 2 flow | Example: 2.0 GPM | 4.0 GPM running total |
| Kitchen faucet flow | Example: 1.0 GPM | 5.0 GPM peak simultaneous flow |
| Desired output temperature | 120°F (DOE suggested setting) | 120°F |
| Incoming winter water temperature | Example: 50°F | Temperature rise of 70°F |
| Unit selection | Rated GPM at a 70°F rise | Choose a model rated for at least 5.0 GPM at a 70°F rise |
Gas supply, venting and electrical capacity for tankless sizing
Tankless water heater sizing also depends on fuel supply. A gas tankless unit needs a gas line large enough for its maximum input, plus correct venting and combustion air. An electric tankless unit sized for a whole home can require substantial electrical capacity and dedicated circuits, which the installer must verify.
This is where many tank-to-tankless projects grow in scope. Our tankless installation and tank to tankless conversion pages explain the typical changes.
Tankless sizing questions to ask the installer
A clear tankless sizing estimate states the fixtures and incoming water temperature the installer assumed, the resulting peak GPM and temperature rise, and the recommended model's rated flow at that rise. That explanation on paper makes tankless proposals from different installers easy to compare side by side.
When you request an estimate through Water Heater Super Pro, we connect you with an independent, licensed installer in our network who will confirm sizing on site. See tankless water heater cost for what drives price.
Tankless Water Heater Sizing FAQs
What size tankless water heater do I need?
Add the flow rates of the hot water fixtures you use at the same time, then find your temperature rise by subtracting incoming winter water temperature from your desired setting. Choose a unit rated for at least that GPM at that rise.
What is temperature rise on a tankless water heater?
Temperature rise is how many degrees the unit must heat incoming water to reach the output temperature. A larger rise, such as in winter, reduces how many gallons per minute the unit can deliver.
Why does my tankless water heater struggle in winter?
Incoming water is colder in winter, so the unit must heat it more. Its GPM capacity drops at a larger temperature rise. A unit sized only for warmer months may fall short when demand peaks in winter.
Can one tankless water heater serve a whole house?
Many homes use a single whole-home gas tankless unit sized for peak demand. Larger homes with high simultaneous use may need a larger unit or more than one. The installer will evaluate your demand and fuel supply.
Should I size a tankless unit with extra margin?
Many installers size on full fixture flow rates, which builds in margin because most uses mix in cold water. Ask the installer to explain the assumptions behind the recommendation.
More Tankless Water Heater Sizing resources
Want a tankless unit sized for your home?
Request an estimate and we will connect you with an independent, licensed installer in our network who can confirm sizing, fuel supply and installation needs.